Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Retina ; 39(1): 98-110, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29190238

RESUMO

PURPOSE: To explore vitreoretinal pathologies and their longitudinal changes visible on handheld optical coherence tomography (OCT) of young children with familial exudative vitreoretinopathy. METHODS: The authors retrospectively analyzed handheld OCT images for vitreoretinal interface and retinal abnormalities and optic nerve head (ONH) elevation. RESULTS: From 26 eyes of 16 children (mean age 32 months) with familial exudative vitreoretinopathy, 10 had ONH dragging on photographs, and in these, handheld OCT revealed temporal and anterior retinal displacement, prominent vitreopapillary adhesion or traction, and retinal nerve fiber layer thickening at ONH margins with adjacent retinal elevation. Despite a nearly normal photographic appearance, handheld OCT revealed ONH elevation with vitreopapillary traction (6/16 eyes), ONH edema (1/16 eye), and retinal vascular protrusion (5/16 eyes). Handheld OCT-visualized vitreous abnormalities (18/26 eyes) were more prevalent at higher stages of disease. Handheld OCT-visualized elevation of ONH and the retina worsened over time in nine eyes and improved in 5/6 eyes after vitrectomy. CONCLUSION: Handheld OCT can detect early ONH, retinal, and vitreous changes in eyes with familial exudative vitreoretinopathy. Contraction of strongly adherent vitreous in young patients with familial exudative vitreoretinopathy appears to cause characteristic ONH dragging and tractional complications without partial posterior vitreous detachment. Vitreopapillary dragging may be visible only on OCT and may progress in the absence of obvious retinal change on conventional examination.


Assuntos
Vitreorretinopatias Exsudativas Familiares/diagnóstico , Angiofluoresceinografia/métodos , Disco Óptico/patologia , Retina/patologia , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Criança , Pré-Escolar , Progressão da Doença , Feminino , Seguimentos , Fundo de Olho , Humanos , Lactente , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Tempo , Corpo Vítreo/patologia
3.
Ophthalmol Retina ; 2(9): 963-971, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30506013

RESUMO

PURPOSE: Bedside examination of premature infants at risk for retinopathy of prematurity (ROP) is predominantly performed with ophthalmoscopic en face viewing of the retina. While postmortem retinal microstructures have been studied at the vascular-avascular junction, a critical location for pathogenesis of ROP, to date this has not been possible in vivo. Here we present bedside, non-sedated in vivo cross-sectional imaging and analysis of retinal microstructures at the vascular-avascular junction in infants with ROP using handheld spectral-domain optical coherence tomography (SDOCT). DESIGN: Prospective observational study. PARTICIPANTS: Eleven preterm infants consented for research imaging during ROP screening examinations. METHODS: We imaged the vascular-avascular junction in the temporal retina using a SDOCT system (Envisu, Bioptigen Inc., NC) in 18 eyes from 11 preterm infants with zone I or II, stage 0 through 4 ROP. B-scan and en face images were analyzed and compared to historical light micrographs. MAIN OUTCOME MEASURES: SDOCT morphology at the vascular-avascular junction. RESULTS: Multiple bedside SDOCT findings at the vascular-avascular junction were comparable to historic light micrographs: thickened inner retinal ridge structure in stage 2 ROP was comparable to thickened vanguard and rear guard cells in micrographs; vascular tufts on the posterior retinal surface in stage 2 ROP, broad arcs of neovascularization above the retina in stage 3 ROP, and splitting of inner retinal layers into clefts on either side of neovascularization mimicked findings of historic light micrographs. A unique findings was thickening of the avascular inner retinal band adjacent to neovascularization. On SDOCT imaging over several weeks, neovascularization and retinal clefts diminished after intravitreal bevacizumab therapy. CONCLUSIONS: Retinal morphology at the vascular-avascular junction imaged with handheld SDOCT is consistent with known histopathology, and provide the advantage of monitoring change in vivo over time. These unique findings provide new insights into preterm retinal neurovascular development in ROP.

4.
Ophthalmol Retina ; 2(5): 401-410, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-31047322

RESUMO

PURPOSE: To evaluate the images produced in an initial surgical series of intraoperative near-real-time volumetric swept-source (SS) OCT imaging. DESIGN: Prospective translational study. PARTICIPANTS: Forty-one consecutive adult patients undergoing vitreoretinal surgery between July 22, 2014, and July 1, 2015, at the Duke University Eye Center who agreed to participate. METHODS: A novel microscope-integrated SS-OCT prototype captured volumetric renderings of imaging of macular surgery in near-real-time and showed them to the surgeon via a heads-up display through the microscope oculars. Then the images were analyzed formally after surgery. MAIN OUTCOME MEASURES: Image quality, successful capture of surgical instruments, maneuvers and associated retinal deformation volumetrically over time, and qualitative image analysis. RESULTS: Volumetric SS-OCT images were graded as acceptable in 92% of patients. Volumetric imaging of scraping and peeling procedures was achieved in 75% and 78% of patients in whom it was performed, respectively. Imaging provided the surgeon with near-real-time volumetric visualization of the position of the instrument relative to the retinal surface, flap initiation, flap removal, and retinal deformation during instrumentation via a heads-up display. CONCLUSIONS: This volumetric, microscope-integrated SS-OCT prototype seems to provide high-detail, near-real-time volumetric imaging of delicate maneuvers during macular surgery.

5.
Asia Pac J Ophthalmol (Phila) ; 6(5): 412-417, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28930381

RESUMO

PURPOSE: To investigate the relationship between intraocular pressure (IOP) and big bubble (BB) formation in a model of deep anterior lamellar keratoplasty (DALK). DESIGN: Ex-vivo. METHODS: Corneoscleral buttons from human donors were loaded onto an artificial anterior chamber connected to a column of balanced salt solution. A surgeon-in-training learned to perform DALK via the BB technique using swept-source microscope-integrated optical coherence tomography (SS-MIOCT) with heads-up display (HUD). DALK procedures were performed at 6 different IOPs (5, 10, 15, 20, 30, or 40 mm Hg; n = 6 per group) in a randomized fashion, with the surgeon-in-training masked to the pressure and guided by SS-MIOCT with HUD. For a subset of corneas within each pressure group, DALK was performed on matching donor tissue at a control IOP. BB diameter was recorded, and a diameter exceeding the trephine diameter was considered optimal. RESULTS: Wilcoxon rank sum test showed a difference in BB diameter among the different pressure groups (mean ± SD of 7.75 ± 1.60, 8.33 ± 1.99, 10.9 ± 0.92, 9.08 ± 1.07, 6.67 ± 3.33, and 3.42 ± 3.77 mm in the 5, 10, 15, 20, 30, and 40 mm Hg groups, respectively; P = 0.0014). Per Tukey test, this difference was attributable to comparisons between the 40 mm Hg group and the 5, 10, 15, or 20 mm Hg groups (P = 0.04, 0.02, 0.0001, 0.004, respectively). CONCLUSIONS: In this ex-vivo model of DALK, the BB technique guided by SS-MIOCT with HUD yielded bubbles of optimal diameters only at physiologic pressures (10‒20 mm Hg). Extremely high IOP (40 mm Hg) resulted in BBs of significantly smaller diameter than BBs obtained at physiologic and low (5 mm Hg) IOPs.


Assuntos
Córnea/cirurgia , Doenças da Córnea/cirurgia , Transplante de Córnea/métodos , Pressão Intraocular/fisiologia , Coleta de Tecidos e Órgãos/métodos , Adulto , Idoso , Córnea/diagnóstico por imagem , Lâmina Limitante Posterior/cirurgia , Dissecação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...